PVC PVC Cables are electrical cables featuring polyvinyl chloride (PVC) insulation for both the inner conductor and the outer sheath, offering excellent flexibility, durability, and fire resistance. Ideal for use in residential, commercial, and industrial applications, they are commonly used in power distribution, internal wiring, and control systems. These cables provide protection against moisture, abrasion, and chemical exposure, making them suitable for indoor and outdoor installations. Optimized keywords: PVC insulated cables, PVC sheathed cables, power cables, PVC electrical wiring, low-voltage PVC cables, and flexible PVC cable
PVC- PVC Cables
Showing all 9 results
- PVC- PVC Cables, Wires & Cables
10mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×10
Diameter of wire (N/mm):7/1.35
Average overall diameter (mm):20.7
Reference weight (kg/km):794
Conductor Resistance (Ω/km) 20℃ Max:1.83
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EHX2M4LB - PVC- PVC Cables, Wires & Cables
16mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×16
Diameter of wire (N/mm):7/1.7
Average overall diameter (mm):23.1
Reference weight (kg/km):1095
Conductor Resistance (Ω/km) 20℃ Max:1.15
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EH1MIHNG - PVC- PVC Cables, Wires & Cables
25mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×25
Diameter of wire (N/mm):10/1.83
Average overall diameter (mm):22.1
Reference weight (kg/km):1270
Conductor Resistance (Ω/km) 20℃ Max:0.727
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EH1WN11G - PVC- PVC Cables, Wires & Cables
35mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×35
Diameter of wire (N/mm):14/1.83
Average overall diameter (mm):24.3
Reference weight (kg/km):1677
Conductor Resistance (Ω/km) 20℃ Max:0.524
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EH8DEU99 - PVC- PVC Cables, Wires & Cables
4mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×4.0
Diameter of wire (N/mm):7/0.85
Average overall diameter (mm):17.1
Reference weight (kg/km):454
Conductor Resistance (Ω/km) 20℃ Max:4.61
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EHQ6T5SN - PVC- PVC Cables, Wires & Cables
50mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×50
Diameter of wire (N/mm):19/1.83
Average overall diameter (mm):27.7
Reference weight (kg/km):2274
Conductor Resistance (Ω/km) 20℃ Max:0.387
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EHRKVXP6 - PVC- PVC Cables, Wires & Cables
6mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×6.0
Diameter of wire (N/mm):7/1.04
Average overall diameter (mm):18.3
Reference weight (kg/km):564
Conductor Resistance (Ω/km) 20℃ Max:3.08
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EH6YVBYW - PVC- PVC Cables, Wires & Cables
70mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×4.0
Diameter of wire (N/mm):7/0.85
Average overall diameter (mm):17.1
Reference weight (kg/km):454
Conductor Resistance (Ω/km) 20℃ Max:4.61
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EHHNBI32 - PVC- PVC Cables, Wires & Cables
95mm x 4 cores STD CU PVC/PVC Insulated Electric Power Cable
4 Cores Power Cable (PVC Insulated) Parameter
Cross-sectional Area (mm²):4×95
Diameter of wire (N/mm):37/1.83
Average overall diameter (mm):36.8
Reference weight (kg/km):4207
Conductor Resistance (Ω/km) 20℃ Max:0.193
Conductor: Cu
Insulation: PVC (Polyvinyl Chloride)
Sheath: PVCDescription of 4 Cores Power Cable (PVC Insulated)
Rated Temperature: 70℃
Rated Voltage: 600/1000V
Reference Standard: GB/T12706, IEC60502, BS6346
Shaped stranded copper conductors
Flame retardant insulated with PVC compound
PVC bedded
Flame retardant PVC sheathed overall
Min.temperature when installation: 0℃
Max. short-circuit temperature: 160℃(max. 5s)
Min. service temperature: -40℃(fixed and protected installations)SKU: EHPD9XCF